Anergy
Showing 121–144 of 182 results
-
Auto Air-Vents, Switches, Test Point
Auto Air-Vent 3/4″ (20mm) dia, PN 10 [AAV20-10]
Features
- Brass construction
- Nylon float/internals
- Built-in check valve
- Sizes 3/8″, 1/2″, 3/4″, 1″
- Maximum operating pressure 10 bar
- Maximum working temperature 110°C
Benefits
- Releases the entrapped air in hydronic systems
- Reduced corrosion
- Better system efficiency
- No air blockages
SKU: n/a -
Microbubble Air & Dirt Separator [PN 16]
Auto Airvent 3/4″, PN 16 (1 no. Required per Air Separator/ Microbubble Air & Dirt Separator of 80mm to 250mm) [AAV-20-16]
Microbubble Air & Dirt Separator [PN 16]Auto Airvent 3/4″, PN 16 (1 no. Required per Air Separator/ Microbubble Air & Dirt Separator of 80mm to 250mm) [AAV-20-16]
Features
- Air separation process based on the concept of coalescence, microbubbles tend to adhere to a surface and then grow together to form larger air bubbles.
- Air separation process based on the concept of coalescence, microbubbles tend to adhere to a surface and then grow together to form larger air bubbles.
- – Large surface area per volume
- – High probability of collision and adhesion of microbubbles, as the fluid flow gets deflected in different directions
- – Minimal resistance to fluid flow
- High capacity auto airvent
- Separation of dirt particles heavier than water is facilitated by
- – Low water velocity
- – Deflection of fluid stream in many different directions by the Pall rings
- – Creation of non-turbulent zone in the extended lower part
- Ball valve at the bottom to drain the collected dirt particles
Benefits
- Removes air microbubbles
- – Increases heat transfer efficiency
- – Reduces chances of air lock
- Reduces corrosion in piping and sludge formation
- Removes impurities heavier than water
- – Prevents choking of strainers
- – Prevents damage to pumps and other equipment
SKU: n/a -
Sensors
Bulb Type Temp. Sensor with Cable Gland (-30?C-70?C) [S-X-B4-T1.G]
The temperature controller shall be electronic, microprocessor based with display working on 24V AC with 0-10V DC output. It shall be capable of accepting inputs from 3 temperature sensors. One temperature sensor for space temperature measurement and the other two temperature sensors for coil inlet and outlet water temperature measurements. The controller shall be capable of comparing the signals and selecting the lower output to prevent excessive water flow through coil. In case of BMS, controller shall accept 0-10V DC signal from BMS.
SKU: n/a -
Auto Air-Vents, Switches, Test Point
Digital Temp. Indicator K type with sensor [DTI-KTYPE-WS]
Features
- Brass body
- Nitrile sealing bushes
- Connection size 1/4″
- Facilitates measurment of temperature and pressure in water or non-corrosive fluids using portable thermometer / pressure gauge
- Maximum operating pressure 16 bar (20 bar optional)
- Maximum working temperature 110°C
Benefits
- Facilitates temperature and pressure measurement during commissioning and operation of HVAC system at various locations using one/few pressure gauges/tehermometers
- Reduced number of gauges/thermometers
- Averts variations in readings due to calibration difference of various pressure gauges/thermometers
- Reduced equipment failures
- Economical
SKU: n/a -
Sensors
Duct mount RH Sensor (30-80%) [S-2-D-H1]
The temperature controller shall be electronic, microprocessor based with display working on 24V AC with 0-10V DC output. It shall be capable of accepting inputs from 3 temperature sensors. One temperature sensor for space temperature measurement and the other two temperature sensors for coil inlet and outlet water temperature measurements. The controller shall be capable of comparing the signals and selecting the lower output to prevent excessive water flow through coil. In case of BMS, controller shall accept 0-10V DC signal from BMS.
SKU: n/a -
Sensors
Duct mount Temp & RH Sensor (-30?C-70?C, 30-80% RH) [S-2-D-T1.H1]
The temperature controller shall be electronic, microprocessor based with display working on 24V AC with 0-10V DC output. It shall be capable of accepting inputs from 3 temperature sensors. One temperature sensor for space temperature measurement and the other two temperature sensors for coil inlet and outlet water temperature measurements. The controller shall be capable of comparing the signals and selecting the lower output to prevent excessive water flow through coil. In case of BMS, controller shall accept 0-10V DC signal from BMS.
SKU: n/a -
Sensors
Duct mount Temp Sensor (-30?C-70?C) [S-2-D-T1]
The temperature controller shall be electronic, microprocessor based with display working on 24V AC with 0-10V DC output. It shall be capable of accepting inputs from 3 temperature sensors. One temperature sensor for space temperature measurement and the other two temperature sensors for coil inlet and outlet water temperature measurements. The controller shall be capable of comparing the signals and selecting the lower output to prevent excessive water flow through coil. In case of BMS, controller shall accept 0-10V DC signal from BMS.
SKU: n/a -
Control Valves High Rangeablity
Electronic Temp. Controller with LED display 24Vac, Range 15?C-35?C, 2 position output [TR-1320D-2-X]
Control Valves High RangeablityElectronic Temp. Controller with LED display 24Vac, Range 15?C-35?C, 2 position output [TR-1320D-2-X]
Features
- – Multi-seat construction (IPR protected).
- – High rangeability/turn-down-ratio above 500(Normal valves-50)
- – Pressure balanced plug construction
- – Low operating force requirement
Benefits
- Can be used against high differential pressure, closer to pump and still control the flow
- Prevents energy wastage
- Very low leakage
- High Δ T ensures high chiller efficiency
- Eliminates need of balancing valve.
SKU: n/a -
Control Valves (for AHU) [3 point op]
Electronic Temp. Controller with LED display 24Vac, Range 15?C-35?C, 3 point output [TR-1320D-3-X]
Control Valves (for AHU) [3 point op]Electronic Temp. Controller with LED display 24Vac, Range 15?C-35?C, 3 point output [TR-1320D-3-X]
Features
- – S.G.Iron contruction
- – Simple, rugged construction
- – Direct connection to rotary actuator
- – Available in 2way(2S) or 3way (3S) Configuration
- – 3way valves suitable for diverting (1 inlet, 2 outlets) or mixing (2 inlets, 1 outlet) application
- – Connection size 25mm – standard & low Kv (SL)
Benefits
- Easy operation
- Highly reliable
- Long life
- Economical
- Easy maintenance
SKU: n/a -
Control Valves (for AHU) [3 point op]
Electronic Temp. Controller with LED display 24Vac, Range 15?C-35?C, 3 point output, suitable for External sensor [TR-1320D-3-E1]
Control Valves (for AHU) [3 point op]Electronic Temp. Controller with LED display 24Vac, Range 15?C-35?C, 3 point output, suitable for External sensor [TR-1320D-3-E1]
Features
- – S.G.Iron contruction
- – Simple, rugged construction
- – Direct connection to rotary actuator
- – Available in 2way(2S) or 3way (3S) Configuration
- – 3way valves suitable for diverting (1 inlet, 2 outlets) or mixing (2 inlets, 1 outlet) application
- – Connection size 25mm – standard & low Kv (SL)
Benefits
- Easy operation
- Highly reliable
- Long life
- Economical
- Easy maintenance
SKU: n/a -
Control Valves & Controller for FCU's
Electronic Temp. controller with LED display, 230Vac, Range 15?C-35?C, 2 position output [TR-1310D-2-X]
Control Valves & Controller for FCU'sElectronic Temp. controller with LED display, 230Vac, Range 15?C-35?C, 2 position output [TR-1310D-2-X]
Features
- – Multi-seat construction (IPR protected).
- – High rangeability/turn-down-ratio above 500(Normal valves-50)
- – Pressure balanced plug construction
- – Low operating force requirement
Benefits
- Can be used against high differential pressure, closer to pump and still control the flow
- Prevents energy wastage
- Very low leakage
- High Δ T ensures high chiller efficiency
- Eliminates need of balancing valve.
SKU: n/a -
Control Valves & Controller for FCU's
Electronic Temp. controller with LED display, 230Vac, Range 15?C-35?C, 2 position output, ON/OFF and 3 speed switches [TR-1312D-2-X]
Control Valves & Controller for FCU'sElectronic Temp. controller with LED display, 230Vac, Range 15?C-35?C, 2 position output, ON/OFF and 3 speed switches [TR-1312D-2-X]
Features
- – Multi-seat construction (IPR protected).
- – High rangeability/turn-down-ratio above 500(Normal valves-50)
- – Pressure balanced plug construction
- – Low operating force requirement
Benefits
- Can be used against high differential pressure, closer to pump and still control the flow
- Prevents energy wastage
- Very low leakage
- High Δ T ensures high chiller efficiency
- Eliminates need of balancing valve.
SKU: n/a -
Control Valves (for AHU) [2-10 BMS Operation]
Electronic Temp.Controller with LED display 24Vac, Range 15?C-35?C, 0-10Vdc output, 0-10Vdc output [TR-1320D-V-X]
Control Valves (for AHU) [2-10 BMS Operation]Electronic Temp.Controller with LED display 24Vac, Range 15?C-35?C, 0-10Vdc output, 0-10Vdc output [TR-1320D-V-X]
Features
- – S.G.Iron contruction
- – Simple, rugged construction
- – Direct connection to rotary actuator
- – Available in 2way(2S) or 3way (3S) Configuration
- – 3way valves suitable for diverting (1 inlet, 2 outlets) or mixing (2 inlets, 1 outlet) application
- – Connection size 25mm – standard & low Kv (SL)
Benefits
- Easy operation
- Highly reliable
- Long life
- Economical
- Easy maintenance
SKU: n/a -
Control Valves (for AHU) [2-10 BMS Operation]
Electronic Temp.Controller with LED display 24Vac, Range 15?C-35?C, 2-10Vdc input (BMS), 0-10Vdc output [TR-1320D-V-B]
Control Valves (for AHU) [2-10 BMS Operation]Electronic Temp.Controller with LED display 24Vac, Range 15?C-35?C, 2-10Vdc input (BMS), 0-10Vdc output [TR-1320D-V-B]
Features
- – S.G.Iron contruction
- – Simple, rugged construction
- – Direct connection to rotary actuator
- – Available in 2way(2S) or 3way (3S) Configuration
- – 3way valves suitable for diverting (1 inlet, 2 outlets) or mixing (2 inlets, 1 outlet) application
- – Connection size 25mm – standard & low Kv (SL)
Benefits
- Easy operation
- Highly reliable
- Long life
- Economical
- Easy maintenance
SKU: n/a -
Control Valves (for AHU) [3 point op]
Extra for Temp, Sensor Bulb Type with Cable Gland [S-X-B4-T1.G]
Control Valves (for AHU) [3 point op]Extra for Temp, Sensor Bulb Type with Cable Gland [S-X-B4-T1.G]
Features
- – S.G.Iron contruction
- – Simple, rugged construction
- – Direct connection to rotary actuator
- – Available in 2way(2S) or 3way (3S) Configuration
- – 3way valves suitable for diverting (1 inlet, 2 outlets) or mixing (2 inlets, 1 outlet) application
- – Connection size 25mm – standard & low Kv (SL)
Benefits
- Easy operation
- Highly reliable
- Long life
- Economical
- Easy maintenance
SKU: n/a -
Control Valves (for AHU) [2-10 BMS Operation]
Extra for Temp, Sensor Bulb Type with Cable Gland [S-X-B4-T1.G]
Control Valves (for AHU) [2-10 BMS Operation]Extra for Temp, Sensor Bulb Type with Cable Gland [S-X-B4-T1.G]
Features
- – S.G.Iron contruction
- – Simple, rugged construction
- – Direct connection to rotary actuator
- – Available in 2way(2S) or 3way (3S) Configuration
- – 3way valves suitable for diverting (1 inlet, 2 outlets) or mixing (2 inlets, 1 outlet) application
- – Connection size 25mm – standard & low Kv (SL)
Benefits
- Easy operation
- Highly reliable
- Long life
- Economical
- Easy maintenance
SKU: n/a -
Microbubble Air & Dirt Separator [PN 16]
Flexair Supervent Max. 3/4″, PN 25 (1 no. required per Air Separator/ Microbubble Air & Dirt Separator of 300mm dia & Above) [SAVM-20]
Microbubble Air & Dirt Separator [PN 16]Flexair Supervent Max. 3/4″, PN 25 (1 no. required per Air Separator/ Microbubble Air & Dirt Separator of 300mm dia & Above) [SAVM-20]
Features
- Air separation process based on the concept of coalescence, microbubbles tend to adhere to a surface and then grow together to form larger air bubbles.
- Air separation process based on the concept of coalescence, microbubbles tend to adhere to a surface and then grow together to form larger air bubbles.
- – Large surface area per volume
- – High probability of collision and adhesion of microbubbles, as the fluid flow gets deflected in different directions
- – Minimal resistance to fluid flow
- High capacity auto airvent
- Separation of dirt particles heavier than water is facilitated by
- – Low water velocity
- – Deflection of fluid stream in many different directions by the Pall rings
- – Creation of non-turbulent zone in the extended lower part
- Ball valve at the bottom to drain the collected dirt particles
Benefits
- Removes air microbubbles
- – Increases heat transfer efficiency
- – Reduces chances of air lock
- Reduces corrosion in piping and sludge formation
- Removes impurities heavier than water
- – Prevents choking of strainers
- – Prevents damage to pumps and other equipment
SKU: n/a -
Control Valves & Controller for FCU's
Microprocessor based controller with LCD display, 230Vac, Range 15?C-35?C, 2 position output, ON/OFF and 3 speed Fan Control [C-1A-T1-D0-F]
Control Valves & Controller for FCU'sMicroprocessor based controller with LCD display, 230Vac, Range 15?C-35?C, 2 position output, ON/OFF and 3 speed Fan Control [C-1A-T1-D0-F]
Features
- – Multi-seat construction (IPR protected).
- – High rangeability/turn-down-ratio above 500(Normal valves-50)
- – Pressure balanced plug construction
- – Low operating force requirement
Benefits
- Can be used against high differential pressure, closer to pump and still control the flow
- Prevents energy wastage
- Very low leakage
- High Δ T ensures high chiller efficiency
- Eliminates need of balancing valve.
SKU: n/a -
Measurement & Recording Data Loggers
Microprocessor based Temp. Sensor Bulb Type with Cable Gland (-) 30?C to 70?C [S-X-B4-T1.G]
Measurement & Recording Data LoggersMicroprocessor based Temp. Sensor Bulb Type with Cable Gland (-) 30?C to 70?C [S-X-B4-T1.G]
Features
- Wide range – temperature, RH, voltage, event
- Small size, poratable, low cost
- On-line & Off-line modes of operation
- Built in clock
- Stand-alone, long operational life
- Re-usable device, replaceable battery
- Non-volatile solid state memory up to 16 K sample point storage capacity
- Easy and instant connection to PC with interface for programming and data download
- Easy to set up windows based software package to analyse data in tabular and graphical format and export to spreadsheet/word processing programs
- Log, store, retrieve, share, transfer and print data
Benefits
- Rugged, maintenance free, long life
- User friendly, easy to program
- Data retention in case of battery failure/replacement
- Easy data sharing and transfer
- Simplified record keeping
- Replaces cumbersome and costly strip-chart recorders
SKU: n/a